Abstract
Abstract Heat transfer and defrosting characteristics of a horizontal single-row array of cooled tubes immersed in a gas-solid fluidized bed, have been studied experimentally. The fluidized bed produces gas-solid particle impinging jets to effectively remove frost layers on the tube surface. It has been verified that frost-free running of the cooled tubes is possible under the conditions of inlet air temperature -7°C, tube surface temperature -7°C and relative humidity 80%. The local contact frequency of particles onto the tube surface was measured by an optical sensing system and the defrosting mechanism of impinging solid particles was observed in detail with a visualization technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.