Abstract

A newly developed polychromatic beam neutron reflectometer CANDOR (Chromatic Analysis Neutron Diffractometer Or Reflectometer) on NG-1 at the NIST Center for Neutron research (NCNR) utilizes a wavelength-sensitive neutron detector consisting of 324 analyzing highly-oriented pyrolytic graphite (HOPG) crystals positioned sequentially in rows. Known for having a small thermal diffuse scattering cross section, HOPG crystals can lead to low signal-to-noise ratios in wavelength-sensitive detectors such as CANDOR. Even though it is possible to mathematically separate the desired signal from thermal diffuse scattering; by cooling the detector array of HOPG crystals in order to minimize the Debye Waller effect generates a better solution to this problem. In this heat transfer analysis study we show, within the instrument design constrains and thermodynamic considerations, technical feasibility and test results for the development of the New Polychromatic Beam Neutron Reflectometer CANDOR (Chromatic Analysis Neutron Diffractometer Or Reflectometer) at the NIST Center for Neutron Research.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.