Abstract

An artificially roughened solar air heater (SAH) with double discrete arc roughness is experimentally explored in this paper. Relative rib altitude (e/Dh ) varies from 0.018 to 0.034, while constant relative rib pitch (P/e), staggered pitch ratio (P′/P) and segment ratio (S′/S ) of 10, 0.5 and 1.6, respectively, are considered. The Reynolds number (Re) varies from 3000 to 14,000. Augmented Stanton number (St) and thermo-hydraulic performance (THPP) with a moderate friction factor (f) are reported for e/Dh of 0.034. The maximum St and f of 2.32 and 3.10 times, respectively, are the result for the rough plate related to basic configuration, while THPP of roughened SAH is augmented up to 1.60. The outcomes of the present roughness are compared with single discrete and continuous arc geometry under identical flow states and confirm the superior performance under the parameters tested. The correlations for heat transfer function (G) and roughness function (R) are also developed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.