Abstract

In this work, the moment and heat transfers of a non-Newtonian fluid flowing in steady laminar regime through a plate heat exchanger at constant wall temperature is studied using CFD. Single-pass U-type plate heat exchangers with multiple flat plates with and without baffles are used. The effect of plates' number and distance between plates on the heat transfer and the pressure drop are investigated. An empirical correlation for the friction factor as a function of the generalized Reynolds number and the ratio between the friction characteristic length and the flow trajectory length is developed. It is found that the dependence of the Nusselt number on the Peclet number can be described by the modified Sieder–Tate equation. Although the flow pattern is highly complex, under an adequate definition of the characteristics parameters, it is possible to establish simple correlations between the dimensionless numbers that characterize the thermal-hydraulic behavior of plate heat exchangers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.