Abstract

In the paper, a hydraulic retarder based organic Rankine cycle (ORC) system is investigated. In order to achieve stable oil output temperature in the evaporator under different hydraulic retarder operating conditions, evaporating pressure is studied to match with a specified evaporator heat transfer area through iterative calculations. An experiment test is a setup to conduct the validation. The results show that regulating evaporating pressure can achieve a target evaporator oil output temperature. However, expander load moment and working fluid mass flow rate (MFR) need to be controlled precisely. With the increase of retarder rotor speed, required evaporating pressure generally decreases, while working fluid MFR increases dramatically. Effects of the changed evaporating pressures and MFR s on expander power output increases from 2.52 kW to 31.43 kW, while cycle thermal efficiency changes slightly in low filling rate condition, from 10.2% to 10.7% for 25% filling condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.