Abstract

A biowaste kill system was implemented to treat biological waste generated from a clinical manufacturing and R&D antibody facility. To confirm that design parameters of this continuous decontamination system are sufficient to inactivate mammalian cell culture waste, bench-scale experiments were conducted. The biowaste kill system heat inactivates mammalian cell cultures before they are piped to a neutralization tank and subsequently released to the sewage system. Heat inactivation of cells is accomplished by exposing cells to 80 degrees C for 1 min. Small-scale heat inactivation studies were performed on CHO, 293-HEK, and hybridoma cells. Cells at 1 x 10(6) cells/mL or 1 x 10(7) cells/mL were exposed to 37, 60, 70, or 80 degrees C for 0, 30, 60, and 120 s. Viability based on trypan blue exclusion method and ability to proliferate was assessed after exposure to heat. Data suggest that exposure of cells to 80 degrees C for 60 s is sufficient to inactivate these cultures before they are released to the sewage system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.