Abstract

A high-pressure flow calorimeter is used to determine isobaric heat capacities for aqueous solutions of some amines such as MEA, DEA TEA, DMAE, MDEA, PZ from T = (293.15 to 353.15) K and up to 25 MPa. The experimental device can measure heat capacities with an estimated total uncertainty better than 1% for a coverage factor k = 2. The isobaric heat capacity values are analysed in conjunction with their temperature and pressure dependencies. Furthermore, empirical equations are proposed to fit isobaric heat capacities as functions of temperature and pressure for given conditions, for this kind of mixtures, obtaining standard deviations within the uncertainty of the measurements. Finally, DMAE shows the highest value of heat capacity and TEA the lowest value, when they are compared at the same conditions of temperature, pressure and composition.