Abstract

A landfill operated in Ste. Sophie, Québec, Canada was instrumented to better understand the waste stabilization process in northern climates. Instrument bundles were placed within the waste to monitor temperature, settlement, oxygen, moisture content, total load, mounding of leachate and electrical conductivity. A finite element model was developed to simulate the heat budget for the first waste lift placed in the winter months and was calibrated using the first 10.5months of collected temperature data. The calibrated model was then used to complete a sensitivity analysis for the various parameters that impact the heat budget. The results of the analysis indicated that the heat required for phase change to thaw the liquid fraction within frozen waste had a significant impact on the heat budget causing sections of waste to remain frozen throughout the simulation period. This was supported by the data collected to date at Ste. Sophie and by other researchers indicating that frozen waste placed during the winter months can remain frozen for periods in access of 1.5years.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.