Abstract

The mud wall is used traditionally for Japanese houses. For effective use, it is necessary to clarify the moisture performance of it quantitatively. Firstly the sorption isotherm and the water vapor permeability of the mud wall were measured. Secondly, the specimen was exposed to the transient absorption and desorption processes including relative humidity of 90%. The processes were numerically analyzed using hygrothermal model for the hygroscopic range, and the calculated results agreed with the experimental results, which suggests the validity of the measured moisture properties and of the application of the hygroscopic model to the conditions including high humidity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.