Abstract
A mathematical model is presented for the vaporisation of liquid from a laminar film flowing down the inside surface of a smooth tube into a countercurrent laminar flow of gas. The partial differential equations that describe temperature and composition distributions are integrated across the tube to give a set of four coupled ordinary differential equations. A numerical method for the solution of the equations is proposed and examined; the method is posed to solve the transient response for heat and mass transfer. A satisfactory solution is found for a range of space and time intervals. The mathematical model has been validated by experimental measurements on a falling film evaporator with evaporation occurring at sub- boiling temperatures from a laminar liquid film into a laminar gas stream. The performance of the evaporator is assessed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.