Abstract

This paper presents an experimental and numerical study on the structural health monitoring of composite patch repairs using chirped fibre Bragg grating (CFBG) sensors. The repair consisted of bonding a pre-cured patch of the same, but thinner, material to a parent GFRP panel containing a machined hole, with the sensors embedded in the bond-line. The repaired coupons were subjected to four-point flexural loading in fatigue. Bond-line delamination cracks (disbonds) initiated at both ends of the patch repair and grew towards the centre of the repair. Predictions of the strain distributions enabled the reflected spectra obtained during damage growth to be predicted with good agreement between theory and experiment. For practical applications when using CFBG sensors to monitor patch repairs, the results suggest that two sensors should be included within the bond-line so that both vulnerable edges of the repair can be monitored using the low-wavelength end of a sensor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.