Abstract
Styrene is a basic building block for manufacturing thousands of products throughout the world. The present study aimed to (1) detect the presence of styrene and/or its metabolites in the workers in one of the Egyptian plastic factories; (2) demonstrate some common health effects of styrene exposure among the same group by some laboratory investigations and compare them with the unexposed healthy individuals; and (3) correlate the duration of styrene exposure and its level in the blood with the severity of the demonstrated health effects. This study was conducted in one of Egyptian plastic factories. The exposed group was 40 male workers, ranging in age from 18 to 33 years (23.20 ± 4.09), working 12 h/day with 1 day off, and working without any protective equipment. A control group of 50 unexposed healthy males matched with the exposed group for age (21-35 yrs (23.40 ± 4.05)), sex, socioeconomic status, and smoking habit is selected. Written individual consent is obtained from all participants followed by (a) a full medical and occupational history and full clinical examination; (b) ventilatory function tests: forced vital capacity (FVC), slow vital capacity, forced expiratory volume in the 1st second (FEV₁)%, FEV₁/FVC%, peak expiratory flow, and mid-expiratory flow 25-75%; (c) analyses of β₂ microglobulin; blood styrene level; and urinary mandelic acid; and (d) cytogenetic study. The study results showed a statistically significant difference between the exposed and the control groups as regard the blood styrene level, urinary mandelic acid level, β₂ microgloblin in urine, and chromosomal study. The study also showed a statistically significant correlation between the duration of styrene exposure and ventilatory function parameters, also between the duration of styrene exposure and some detectable chromosomal aberrations. Our study recommends the implementation of preemployment and periodic medical examinations and health education programs using personal protective equipments and following the recommended allowable concentrations of styrene exposure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.