Abstract

We studied the healing strength and histological changes of digital flexor tendons repaired using Kessler (core suture knots placed over the tendon surface) and modified Kessler (core suture knots placed between two tendon ends) in 31 long toes of chicken. Four weeks after surgery, the healing tendons were measured in a tensile testing machine, and the adhesion formation and histological changes were observed. The strength of the Kessler repairs was significantly greater than that of the modified Kessler repairs with a 35% mean difference. No significant difference was found between the adhesion scores of the tendons repaired with both techniques. In histological sections, the arrangement of collagen fibers in the modified Kessler repair group was more disordered. We conclude that the tendons repaired with the Kessler method are stronger than those with the modified Kessler technique. The knots between tendon ends are detrimental to the early healing strength of digital flexor tendons.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.