Abstract

A methodology for the determination of five aldehydes in urine has been developed based on the coupling of a headspace generation sampler with a gas chromatography–mass spectrometry system equipped with a programmed temperature vaporizer. This instrumental configuration minimizes sample manipulation and allows the determination of these compounds without the need for a derivatization step so that the methodology is largely shortened and simplified. An experimental design was carried out in order to optimize the headspace sampling. Sample matrix effect was eliminated by means of dilution of urine samples. The calibration models displayed good linearity (0.1–10μg/L) and their validity was checked using ANOVA, and it was observed that they did not exhibit any lack of fit. The LODs obtained ranged between 0.04 and 0.08μg/L and the LOQs between 0.12 and 0.24μg/L. The accuracy of the method was evaluated in terms of apparent recoveries which were between 86 and 120%. The method developed was applied to the analysis of 17 samples of urine from different subjects in order to quantify these endogenous compounds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.