Abstract

A headspace method to measure the carbon dioxide evolved in a screening biodegradability test is described. Use was made of conventional serum bottles, sealed with butyl rubber septa, through which headspace samples were taken after acidification and equilibration of the test solution. For each determination a serum bottle was sacrificed. The gas samples were injected directly into the reaction chamber of a carbon analyzer. Eighteen chemicals varying in solubility and biological properties were submitted to the test. Where possible, mineralization of test compounds was monitored through dissolved organic carbon analysis in addition to CO 2 analyses. The reliability of the method was verified by comparing the measured concentration of dissolved inorganic carbon of a standard sodium carbonate solution with values calculated from measured concentrations of carbon dioxide in the headspace after acidification. Results of biodegradability testing are discussed in view of the suitability of the method to poorly soluble compounds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.