Abstract
During the second stage of labor, in case of a need for a fetal extraction at midcavity, the choice of attempting the procedure between operative vaginal delivery and cesarean delivery is difficult. Moreover, guidelines on this subject are not clear. This study aimed to identify antenatal and intrapartum parameters associated with a failed midcavity vacuum-assisted delivery and its association with maternal and neonatal adverse outcomes. This was a single-center, retrospective, cohort study conducted at a tertiary maternity hospital in France from January 2010 to December 2020. Women with singleton pregnancies under epidural analgesia with nonanomalous cephalic presenting fetuses and gestational ages at ≥37 weeks of gestation, who were submitted to midcavity vacuum-assisted delivery, were included. Following the American College of Obstetricians and Gynecologists definition, midcavity was defined as the presenting part of the fetus (ie, the fetal head) found at stations 0 and +1. For research purposes, all patients were submitted to transperineal ultrasound to evaluate the head-to-perineum distance, however, this measurement did not affect the decision to perform a midcavity vacuum-assisted delivery. The primary outcome of the study was failed midcavity vacuum-assisted delivery leading to cesarean delivery or the use of a different instrument to achieve vaginal delivery. Overall, 951 cases of midcavity vacuum-assisted delivery were included in this study. Failed midcavity vacuum-assisted delivery occurred in 242 patients (25.4%). Factors independently associated with failed midcavity vacuum-assisted delivery included maternal height (adjusted odds ratio, 0.96; 95% confidence interval, 0.94-0.99; P=.002), duration of the active phase of the first stage of labor (adjusted odds ratio, 1.11; 95% confidence interval, 1.05-1.17; P<.001), nonocciput anterior fetal head position (adjusted odds ratio, 1.47; 95% confidence interval, 1.06-2.04; P=.02), z score of the head-to-perineum distance (adjusted odds ratio, 1.23; 95% confidence interval, 1.05-1.43; P=.01), and birthweight of >4000 g (adjusted odds ratio, 2.04; 95% confidence interval, 1.28-3.26; P=.003). Women submitted to a failed midcavity vacuum-assisted delivery were more likely to have a major postpartum hemorrhage (7.1% vs 2.0%; P<.001), whereas neonates were more likely to have an umbilical artery pH of <7.1 (30.5% vs 19.8%; P=.001), be admitted to the neonatal intensive care unit (9.6% vs 4.7%; P=.005), and have a severe caput succedaneum (14.9% vs 0.7%; P<.001). Subgroup analysis on all patients with a fetal head station of 0 found that the head-to-perineum distance was the only independent variable associated with failed midcavity vacuum-assisted delivery (adjusted odds ratio, 1.66; 95% confidence interval, 1.29-2.12; P<.001). The area under the receiving operating characteristic curve of the head-to-perineum distance in this subgroup population was 0.67 (95% confidence interval, 0.60-0.73; P<.001), and the optimal cutoff point of the head-to-perineum distance measurement discriminating between failed and successful midcavity vacuum-assisted deliveries was 55 mm. It was associated with a 0.90 (95% confidence interval, 0.83-0.95) sensitivity, 0.19 (95% confidence interval, 0.14-0.25) specificity, 0.36 (95% confidence interval, 0.30-0.42) positive predictive value, and 0.80 (95% confidence interval, 0.66-0.90) negative predictive value. Study data showed that a high fetal head station, measured using the head-to-perineum distance, and a nonocciput anterior position of the fetal head are independently associated with failed midcavity vacuum-assisted delivery. The result supported the systematic assessment of the sonographic head station and position before performing a midcavity vacuum-assisted delivery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.