Abstract

The preferred nuclear medicine method for identification of hyperfunctioning parathyroid glands in hyperparathyroidism (HPT) develops continuously in relation to the technological progress. Diagnostic methods based on PET/CT have during recent years evolved with new tracer possibilities competing with traditional scintigraphic methods. This investigation is a head-to-head comparison of Tc-99m-sestamibi SPECT/CT gamma camera scintigraphy (sestamibi SPECT/CT) and C-11-L-methionin PET/CT imaging (methionine PET/CT) for preoperative identification of hyperfunctioning parathyroid glands. The study is a prospective cohort study including 27 patients diagnosed with primary hyperparathyroidism (PHPT). Two nuclear medicine physicians assessed all examinations independently and blinded. All scanning assessments were matched to the final surgical diagnosis as confirmed by histopathology. Biochemical monitoring of the therapeutical effects was performed preoperatively by PTH-measurements and followed postoperatively for up to 12 months. Comparisons were made for differences in sensitivity and positive predictive value (PPV). Twenty-seven patients (18 females, 9 males; mean age (range): 58.9 years (34.1-79)) were enrolled into the study. The 27 patients had a total of 33 identified sites of lesions of which 28 (85%) turned out to be histopathological verified hyperfunctioning parathyroid glands. The sensitivity and PPV for sestamibi SPECT/CT were 0.71 and 0.95; that of methionine PET/CT was 0.82 and 1, respectively. Both sensitivity and PPV were slightly lower for sestamibi SPECT/CT than for methionine PET PET/CT (-0.11, 95% confidence interval (95% CI): -0.29 to 0.08; -0.05, 95% CI: -0.14 to 0.04, respectively), but not to a statistically significant extent (p=0.38 and p=0.31). The sensitivity and PPV for diagnostic CT were 0.64 (95% CI: 0.44 to 0.81) and 1 (95% CI: 0.81 to 1). Methionine PET/CT performed comparable to sestamibi SPECT/CT with respect to identification and localization of hyperfunctioning parathyroid glands prior to surgery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.