Abstract
We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)-based adaptive strategy with an average patient anatomy to overcome possible target underdosage. For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)-to-planning target volume margins of 5, 3, and 0mm. We applied b-spline CBCT-to-computed tomography (CT) deformable registration to allow recalculation of the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2Gy were identified as candidates for adaptive replanning.For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Margin reduction from 5mm to 3mm to 0mm generally led to an organ-at-risk (OAR) mean dose (Dmean) sparing of approximately 1Gy/mm.CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2Gy (parotid glands, Dmean) for all applied margins. Loss of CTV coverage >2Gy was found in 1, 3, and 7 of 73 CTVs, respectively.Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2Gy of initially planned. Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Radiation Oncology*Biology*Physics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.