Abstract

RECENT REPORTS have shown that the use of a starch-derivative powder, instead of talc, for the hands and surgical gloves has not eliminated all the complications associated with the latter. Goodman et al<sup>1</sup>reported that a commercial starchderivative, absorbable dusting powder (Bio-Sorb), frequently used on surgical gloves, is not inert and its use results in severe granulomatous lesions and adhesions in the abdominal cavity. Likewise, petechial hemorrhages of the face and retina are known to occur after carotid angiograms. This has been attributed to the contamination of contrast media and catheters by glove powder.<sup>2</sup>Although serious consequences have not been reported, it is possible that damage to vital organs may be produced. We are not aware of similar reports in relation to renal angiography. This communication reports a case of petechiae and focal glomerulitis due to starch granules in a kidney removed 20 hours after renal angiography. Injection

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.