Abstract
This article presents an investigation of the actual cooling effect on a lab-scale prototype of LPG-fueled vehicles. The cooling effect is obtained from heat absorption by LPG on the vaporizer. Water with a mass flow rate of 1, 2 and 3 lpm is flowed from the cooling box to the LPG evaporator and flow back to the cooling box. The car used in this study has a capacity of 1500 cc that rotates 1000, 1500, and 2000 rpm. The results showed that there was a relationship between cooling power with the increase in engine speed and mass flow rate of water that crosses the evaporator. The biggest cooling power is 378 Watts at 1000 rpm with a water mass flow rate of 3 lpm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.