Abstract

In this paper, an optimal solution to the harmonic reduction problem in a cascaded multilevel inverter with non-equal DC sources using a genetic algorithm (GA) is presented. Switching angles are generated for different values of modulation index by the proposed algorithm, considering minimum voltage total harmonic distortion (THD) whereas selected harmonics are controlled within the allowable limits at all desired modulation indices including the point of discontinuity. Results are stored as a look-up table to be used to control the inverter for a certain operating point. The computed angles are used in a simulated circuit in Matlab\Simulink to validate the results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.