Abstract

This paper represents analysis of the asymmetrical voltage-cancellation (AVC) control technique to achieve lower harmonic components in output power of full-bridge series resonant inverters. Minimization of the total harmonic distortion (THD) is achieved by means of varying the control angles. This would be yield to high efficiency, rapid heating and high performance temperature control in induction-heating appliance. Harmonic components in the output voltage of the full-bridge series resonant inverters are analyzed in detail and comparative study shows that the AVC control technique achieves lower THD than conventional fixed-frequency control strategies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.