Abstract

Since the penetration of photovoltaic (PV) systems in the low voltage (LV) distribution network is increasing, the need to register and model the contribution of these systems to the harmonic distortion of current and voltage waveforms is becoming an up-to-date issue. As PV systems incorporate power conditioning units, which are harmonic generating devices, they will have an influence on quality of supply, reliable operation of system equipment as well as component life expectancy. This paper investigates the harmonic impact of a 20 kWp PV system connected to the LV distribution network in Greece. The harmonic behavior of the PV plant as a function of the solar radiation under several weather conditions is analyzed. Measurements results are compared to those obtained from the power simulator package PSIM <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">copy</sup> . The level of penetration of PV systems in the LV distribution network without harmonic limits been exceeded is investigated.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call