Abstract
In external rotor permanent magnet synchronous motors, also the higher frequency harmonics of the radial forces generate considerable resonant vibrations and acoustic noise. Therefore, diversity of spatial and especially frequency harmonic ordinal numbers of representative slot and pole number combinations are derived analytically with open-circuit and under load. Amplitudes of radial force waves are calculated by means of the finite element method and two-dimensional Fourier analysis. The obtained results confirm the analytical investigation. Determining factors on amplitudes are analyzed on a machine having 12 slots, 10 poles and a double-layer winding. Higher frequency harmonics can be significantly affected by pole and tooth shaping. With open-circuit, the calculations are validated by experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.