Abstract

Harmonic distortion correction (HDC) is an effective digital calibration technique to estimate and correct errors and distortions in an analog circuit. However, the convergence time is still a concern. In this paper, we propose the injection of a periodic 3-bit gray code sequence for HDC to digitally calibrate an 8-bit delay line ADC. In our simulation results, digital calibration with the gray code injection improves SNDR and SFDR to 42.5 dB and 45.4 dB, respectively, compared with the original SNDR of 25.6 dB and the original SFDR of 25.7 dB, with a 13.5 milliseconds calibration time, which is 64X faster than with injection of pseudorandom numbers (860 milliseconds). Also the SNDR converges to 41.6 dB after averaging 2 24 samples, while the SNDR with injection of pseudorandom numbers converges to 41.5 dB after 2 37 samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.