Abstract

This paper proposes harmonic comparison between symmetrical and asymmetrical CHB MLI using multiple carrier based phase disposition PWM technique (PDPWM). Topologies of different multilevel inverter are reported in the literature, but mainly this work focuses on the harmonic comparison of symmetrical and asymmetrical cascaded MLI with same count of sources and switches. In this paper, PWM switching technique for harmonic comparison of both symmetrical and asymmetrical cascaded MLI is PD. Total harmonic distortion is analyzed in FFT window. Results are observed in SIMULINK/MATLAB software. In these comparative results we can see that an asymmetrical configuration is producing higher voltage levels in voltage output with equal quantity of component compared with the 5-level symmetric inverter and this could lead towards the reduction in harmonic content of output voltage. The benefits of this method of control are applicability and simplicity for n-levels MLI, with no any considerable change in the control circuitry. The experimental measurement results validate proper operation of the discussed MLI.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.