Abstract

This paper discusses implementation of a method for analysis of the harmonic distortion factor of output voltage in a synchronous generator. A two-dimensional finite-element modeling is used for calculating the stator coil flux linkages and consideration is given to rotor movement. The treatment of the motion employs the moving-band technique. To illustrate the proposed method, the distortion factor of the output voltage waveform in a 150 kW salient pole synchronous generator has been computed and found to be consistent with experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.