Abstract

Runaway electrons (REs) generated during disruptions pose a significant safety threat to tokamaks, as they can melt and damage the plasma-facing components (PFCs). Therefore, studying RE behavior is crucial for fusion devices. The interaction between REs and the first wall/PFCs results in the emission of high-energy X-rays, known as bremsstrahlung. To investigate RE behavior, it is necessary to quantitatively evaluate the emission of hard X-rays. A real-time hard X-ray spectrometer, utilizing a LaBr3 detector, has been successfully developed for studying REs on the HL-2M tokamak. This spectrometer has a counting rate capability reaching 3 MHz, with an energy resolution of 3.3% at 662 keV (137Cs). The time resolution for energy spectrums is as short as 1 ms. During the HL-2M discharge, observations were made on the hard X-ray energy spectrum, and by analyzing the spectrum within the energy range of 250 keV to 750 keV, the temperature of the corresponding REs was deduced.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.