Abstract
PurposeTo describe a case of intraocular lens (IOL) tilt following transscleral IOL fixation with the Yamane technique and subsequent correction of tilt using 810-nm endoscopic diode laser. ObservationsOur patient required lens exchange and secondary IOL implantation due to a dislocated 1-piece IOL in the bag causing iris chafe. After routine IOL fixation with the Yamane technique and a Zeiss CT Lucia 602 lens, the IOL tilted significantly in the immediate postoperative period. The lens tilt was subsequently corrected in the operating room using endolaser to melt and reshape (cure) the optic-haptic junction. ConclusionsIOL tilt is a known complication associated with the Yamane technique, which has seen increasing reports with the Zeiss CT Lucia 602 lens. Using endolaser to reconfigure the tilted optic into the desired orientation is a more novel procedure that can correct the lens tilt without the need for IOL exchange.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.