Abstract

Suitable detectors are needed to support survey needs of incident responders and health care personnel who may receive patients from an incident with exposures to hazardous chemicals. In the health care setting, such a detector would avoid cross-contamination to workers, patients, and to the treatment facility and associated equipment. An ideal survey detector would be sensitive, hand-held, capable of extended battery operation, and would provide a nearly immediate detector response on exposure to a broad range of high-concern chemicals. For responders, important capabilities would include quantitative measurement of gas/vapor contamination, and for both response and health care settings, qualitative detection of contaminated people and objects. In this study, the operating characteristics of photoionization detector (PID) instruments were examined using O-isopropyl methylphosphonofluoridate (sarin) in a laboratory setting. Instrument response factors were calculated for quantitation of airborne sarin, and speed of detector response and recovery were examined with point-contaminated cloth material. By sampling a range of sarin-contaminated air, calculated isobutylene unit response factors for high-and moderate-sensitivity commercial PID instrument types were 11.3 and 14.0 (dry air) and 20.1 and 44.4 (50% relative humidity), respectively. Response of the PID systems was highly correlated to concentration sampled, with R2 values greater than or equal to 0.997 for all combinations of PID detector type and humidity. While not sensitive enough to warn the unprotected public against a chemical with an extremely low “safe” exposure concentration, quantitation with available PID instruments could be useful to quickly prioritize corrective measures for a PID-detectable chemical. Qualitative survey characteristics were examined for the more sensitive PID tested using a piece of cloth material contaminated by a 1.0 μ L droplet of liquid sarin. Rapid response and recovery times (seconds) were observed when the sampling inlet was moved close to and away from the point of contamination. Within the health care setting, hand-held PID instruments could fill an important and currently unmet need as a point source detector for liquid contamination from extremely dangerous chemicals to help identify contaminated surfaces and limit secondary contamination and exposures.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call