Abstract

PurposeTo assess a radiomic machine learning (ML) model in classifying solid adrenal lesions (ALs) without fat signal drop on chemical shift (CS) as benign or malignant. Method55 indeterminate ALs (21 lipid poor adenomas, 15 benign pheocromocytomas, 1 oncocytoma, 12 metastases, 6 primary tumors) showing no fat signal drop on CS were retrospectively included. Manual 3D segmentation on T2-weighted and CS images was performed for subsequent radiomic feature extraction. After feature stability testing and an 80–20% train-test split, the train set was balanced via oversampling. Following a multi-step feature selection, an Extra Trees model was tuned with 5-fold stratified cross-validation in the train set and then tested on the hold-out test set. ResultsA total of 3396 features were extracted from each AL, of which 133 resulted unstable while none had low variance (< 0.01). Highly correlated (r > 0.8) features were also excluded, leaving 440 parameters. Among these, Support Vector Machine 5-fold stratified cross-validated recursive feature elimination selected a subset of 6 features. ML obtained a cross-validation accuracy of 0.94 on the train and 0.91 on the test sets. Precision, recall and F1 score were respectively 0.92, 0.91 and 0.91. ConclusionsOur MRI handcrafted radiomics and ML pipeline proved useful to characterize benign and malignant solid indeterminate adrenal lesions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call