Abstract

Neonatal hypothermia is the fourth leading causes of neonatal death in Nepal. Thus, it is the caregivers' responsibility to identify the hypothermia by using valid and less time consuming method like hand-touch method. Therefore, we examined the diagnostic validity of hand-touch method against low-reading mercury (LRM) thermometer for detecting neonatal hypothermia. We assessed neonate's temperature first by hand-touch method, then by LRM thermometer and tympanic thermometer among 100 full-term neonates, delivered within 24 h in Maternity Ward of Tribhuvan University Teaching Hospital, Nepal. We used World Health Organization (1997) criteria for classification of neonatal hypothermia. The sensitivity and specificity of the hand-touch method for detection of neonatal hypothermia were 95.6% and 70.1% against LRM thermometer and 76.6% and 83% against the tympanic thermometer, respectively. Touching method is practical and therefore has a good diagnostic validity; it can be introduced in essential newborn care package after giving adequate training to caregivers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.