Abstract

Unexplained visual acuity loss or a complaint of intermittent blurred vision experienced by the contact lens corrected aphakic may all too frequently be caused by surfacing imperfections in the front surface optical zone of these high-plus corneal lenses. The lensometer is a highly inadequate instrument for the optics of a corneal contact lens; yet it is usually the only instrument used for this purpose. The can be used to check the back-surface optics of a corneal lens; yet it is rarely used to check anything but the radius of the central 3 or 4 mm of the rear surface of the lens. The radiuscope is almost never used to check the peripheral optical portions of the front surface. It can be particularly revealing and useful in front surface checking of the periphery of the lenticular zone of the high-plus corneal lens. After suspecting flaws in peripheral optical quality

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.