The Hall effect is used to measure the electron mobility in HfO/sub 2/ based n-channel field effect transistors with poly-Si gates. Large deviations between measured Hall and drift mobilities are explained by the presence of high concentrations of nonfixed charge (up to 4/spl times/10/sup 12/ cm/sup -2/). Simulated mobility curves show that the observed concentrations of fixed and nonfixed charge can estimate the measured mobility significantly better than if only the fixed charge concentration is used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.