Abstract

A 22-year old man presented with a massive haemothorax 25 days after bullectomy for a spontaneous pneumothorax. Thoracoscopic surgery revealed ongoing bleeding from the chest wall caused by a sharp edge of the Endoloop Ligature (Ethicon Endo-Surgery) used to resect the remaining small part of the lung at the earlier staple bullectomy. The point where bleeding was occurring was clipped and covered using a collagen patch coated with human fibrinogen and thrombin. The protruding sharp edge of the Endoloop was excised together with the surrounding lung tissue, using a stapler. Although prevention of this type of complication is difficult, awareness of the potential problem may help in managing such extremely rare events.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.