Abstract
We determined (a) the haemodynamic responses to intubating laryngeal mask (ILM) airway insertion/intubation and removal in anaesthetized patients, and (b) whether the timing of ILM removal influences these responses. One-hundred and twenty patients without cardiovascular disease were studied. ILM airway insertion/intubation was 5 min after induction with propofol 2 mg kg(-1) and maintenance of anaesthesia with sevoflurane 2% in oxygen 33% and nitrous oxide. Patients were randomly assigned for removal of the intubating laryngeal mask airway at 1, 3 and 5 min after successful intubation. Systolic and diastolic arterial pressures and heart rate were recorded preinduction (baseline), before ILM airway insertion/intubation, at 1-min intervals after insertion/intubation, and at 1-min intervals for 5 min after ILM removal. ILM insertion was successful at the first attempt in all patients, but 46 patients required more than one intubation attempt. Compared with baseline values, there were no increases in systolic or diastolic arterial pressure, but there was an increase in heart rate 1 min after ILM insertion/intubation (9%, P<0.001) and 1 min after ILM removal (8%, P<0.01). There was a significant increase in systolic and diastolic pressures and heart rate 1 min after ILM insertion/intubation (30%, 31% and 15%; all: P<0.002) compared with before ILM insertion/intubation values and 1 min after ILM removal (9%, 8% and 7%; all P<0.05) compared with 1 min after ILM insertion/intubation values. Removal of the ILM 1 min after successful intubation resulted in higher arterial pressure compared with removal at 3 min (systolic arterial pressure 10% higher for 1 min, P = 0.01) and 5 min (systolic arterial pressure 10-23% higher for 3 min, P<0.01; diastolic arterial pressure 10-20% higher for 4 min, P>0.02), but there were no differences in heart rate between groups. Systolic and diastolic arterial pressures were greater if more than one intubation attempt was required. Early removal or multiple intubation attempts did not exceed baseline haemodynamic values. We conclude that ILM insertion/intubation and removal in anaesthetized patients produces little or no haemodynamic response, even if multiple intubation attempts are required. The timing of removal exerts a small, but clinically unimportant influence on these responses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.