Abstract

Intra-aortic balloon pump (IABP) devices are commonly used in patients with heart failure related cardiogenic shock (HF-CS), including those with out-of-proportion right ventricular (RV) dysfunction. Pulmonary artery pulsatility index (PAPi) is a haemodynamic surrogate for RV performance. We aimed to assess short-term haemodynamic changes in patients with HF-CS following IABP support stratified by baseline PAPi. This is a single-centre study of 67 consecutive patients with HF-CS who underwent IABP placement between 2020 and 2022. The primary aim was haemodynamic changes of specific variables on pulmonary artery catheter monitoring over 72h following IABP placement. Secondary aims were clinically significant changes in diuretic regimens, changes in inotropes or vasopressors at 72h following IABP, along with clinical outcomes. Prior to IABP placement, 57% of the total cohort (median age 59years [48, 69], 31% female) had Society of Cardiovascular Angiography and Interventions Stage C HF-CS. Thirty-eight (56%) patients had a PAPi <2.0. Following 72h of IABP support, the PAPi <2.0 group had an observed significant decrease in central venous pressure (CVP; 20 to 12mmHg, P<0.001) and mean pulmonary artery pressure (mPAP; 37.5 to 28.5mmHg, P=0.001), and an increase in PAPi (1 to 1.6, P=0.001). No significant change in cardiac index (CI; 2 to 2.1L/min/m2, P=0.31) was observed. The PAPi ≥2.0 group (N=29) had no observed significant change in CVP (10 to 8mmHg, P=0.47), or PAPi (2.6 to 2.8, P=0.92), but there was a significant improvement in CI (1.9 to 2.5L/min/m2, P=0.004) along with reduction in mPA (37 to 29mmHg, P=0.03). The PAPi <2.0 group had a significant increase in diuretic requirement (52.6% vs. 20.7%, P=0.01) and numerically greater addition of inotropes/vasopressors (47.3% vs. 34.4%, P=0.07) compared with the PAPi ≥2.0 group at 72h following IABP placement. Significantly more patients in the PAPi ≥2.0 group underwent left ventricular assist device (55.2% vs. 26.3%, P=0.02), with no overall significant differences observed in escalation to veno-arterial extracorporeal membrane oxygenation, 30-day mortality, renal replacement therapy post-IABP, or rates of heart transplantation. IABP devices in those with HF-CS and low or abnormal PAPi may provide modest short-term haemodynamic benefits without significant improvement in CI, along with greater need for adjustment in medical therapeutics to achieve haemodynamic optimization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.