Abstract

The Renewable Distributed Generation (RDG), such as production of electricity in the vicinity of the load, it is particularly beneficial when the distribution network is "weak" facing specific demands, as in hydrogen production systems connected to rural electrification networks. In these areas, the wind resource may be suitable for this type of generation. This work proposes the topology and the operation and control strategy for a hydrogen production station, "assisted" by a weak AC grid and "powered" by a variable speed wind turbine based on a three-phase double stator induction machine. The wind energy conversion is optimized through adequate control of the generator. The electrolyzer current is regulated for the maximum utilization of the generated power. The high-speed power fluctuations by turbulence are compensated through a controlled energy storage system based on a flywheel. In addition, the system configuration, its operation mode and control, and simulation results are presented.