Abstract

The behavior of rewetting on a high superheated and dry surface, focusing on rewetting temperature just as collapse of saturated and subcooled film boiling was investigated experimentally and analytically. Saturated and subcooled impingement jet experiments were conducted by using a Silicon wafer with 20mm length, 20mm width and 0.5mm thickness and pure water at atmospheric condition. Temperature of the test heater was measured by using a commercial separated-type infrared thermometer from a back side of it. The present experimental results showed that as the liquid subcooling was high, MHF temperature was higher. Namely, the experimental results agreed with Dhir-Purohit's correlation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.