Abstract

We have been developing an in-plain thermal conductivity measuring method of flat plate specimen such as printed wiring board (PWB) by straight fin temperature fitting method. We applied one point radiation thermometer axially moving automatically for measuring the axial temperature distribution of the speciment. From thr experimental investigation, we obtained the following conclusions. (1) By applying the temperature fitting to the range of above 5K temperature rise, the in-plane thermal conductivity of the specimen was obtained within 10% dispersion under the condition of the fin efficiency of 0.2〜0.85 in spite of temperature fluctuation of ±1K of one point radiation thermometer. (2) By using mean heat transfer conductivity of the specimen was obtained within 10 % dispersion under fin efficiency lower than 0.2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.