Abstract

This paper presents a H∞ loop-shaping controller for controlling dc-link voltage by regulating the switching signal of the inverter associated with a grid-connected single-phase photovoltaic system. To facilitate a robust control design, state-space realisation of the system model is made with uncertainties represented by linear fractional transformation. The controller is achieved through H∞ synthesis followed by obtaining desired loop shapes through the choice of the proper weighting functions. The controller order is reduced by Henkel-norm method for facilitating its practical implementation. Controller performance is evaluated through carrying out simulations on MATLAB/Simulink platform under standard and changing atmospheric conditions, and fault condition.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call