Abstract
The purpose of the study is to quantify occlusal errors seen, during the processing of complete denture. Maxillary and mandibular complete dentures were fabricated for 30 subjects. Anterior and posterior markings were made on articulator and the distance was measured from these points before and after processing of complete dentures. Occlusal errors following processing of complete dentures was determined by subjecting the values obtained to statistical analysis using paired t-test. The results indicated the existence of discrepant amount of occlusal errors following processing of complete denture and statistical test applied was paired t-test, p-values obtained are, p=0.00 anterior reference markings and p=0.006 for posterior reference markings (p ≤ 0.001 highly significant). The processing errors are inevitable. Hence for patient comfort, laboratory remounting is an important procedure that needs to be followed as a regular step after processing of each and every denture.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.