Abstract
We present guiding measurements of 0.8-μm, 100-fs pulses through LiF microcapillaries using discharge plasma. We inspect the transmission at conditions fit for soft-x-ray lasing. While up to 45% transmission is observed for input intensities of 1×1018 W/cm2, only ∼2% of the energy is contained in the small guided mode of 25 μm (FWHM). We investigate the dependence of the guiding on input intensity and focusing geometry. The transmission decreases for unmatched focal spots and as the intensity increases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.