Abstract

The RFX experimental results at the highest plasma current (about 1 MA) and for relatively long pulses (150 ms) show the presence of high power flux densities on the first wall, up to 40 MW/m2 averaged on a single tile.Detailed numerical analyses have been carried out to simulate the thermal response of a single tile. The results of sensitivity analyses give information on the radiative and convective power flux intensities and the related first wall temperature distributions.The experimental data and the results of thermal analyses give quantitative information and qualitative guidelines for the design of an optimized first wall for a RFP device.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.