Abstract

Cases in which an anomalous single coronary trunk arises from the ascending aorta are extremely rare. In percutaneous coronary intervention for the lesion of a coronary artery anomaly, several problems may occur, including selection of a guide catheter, insufficient backup force, and difficulties of stent delivery. The GuideLiner catheter, which is a coaxial guide extension having the advantage of rapid exchange, facilitates coronary intervention for complex lesions. We report a case of angina having a lesion in the left anterior descending artery of a single coronary trunk arising from the ascending aorta. We successfully performed revascularization by using the GuideLiner catheter.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.