Abstract

Intraoperative monitoring (IOM) is commonly used during lumbar fusion surgery for the prevention of nerve root injury. Justification for its use stems from the belief that IOM can prevent nerve root injury during the placement of pedicle screws. A thorough literature review was conducted to determine if the use of IOM could prevent nerve root injury during the placement of instrumentation in lumbar or lumbosacral fusion. There is no evidence to date that IOM can prevent injury to the nerve roots. There is limited evidence that a threshold below 5 mA from direct stimulation of the screw can indicate a medial pedicle breach by the screw. Unfortunately, once a nerve root injury has taken place, changing the direction of the screw does not alter the outcome. The recommendations formulated in the original guideline effort are neither supported nor refuted with the evidence obtained with the current studies.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call