Abstract

Endosseous dental implants with rough surfaces have been designed to improve early healing, especially in areas of poor bone or insufficient bone quantity. The aim of this study was to histomorphometrically assess the bone-to-implant contact on 3 different rough-surfaced implants following guided bone regeneration. Mandibular premolars and first molars were extracted in 12 dogs, and healing was allowed for 6 months. Six implant osteotomy sites were prepared, 3 per side, followed by the creation of 7.3 mm wide by 5 mm deep surgical defects in the coronal section of the osteotomy sites. Ten-mm long titanium screw-type implants with titanium plasma-sprayed (TPS), hydroxyapatite-coated (HA), or acid-etched (AE) surfaces were placed; the surrounding defects were filled with canine demineralized freeze-dried bone allograft; implants/grafts were covered with expanded polytetrafluoroethylene membranes; and the tissue was closed. Following a healing period of 4 months, the animals were sacrificed and mandibular blocks were harvested for histomorphometric analysis. The mean percentage of bone-to-implant contact in the defect and non-defect areas for the different implant surfaces was: AE 16.24% defect, and 28.78% non-defect; TPS 25.08% defect, and 16.96% non-defect; and HA 48.25% defect and 26.60% non-defect. Within the defect, the mean difference in the bone-to-implant contact was significant for HA compared to TPS (P < 0.0001) and HA versus AE (P < 0.0001); TPS versus AE was not significant (P = 0.063). In the non-defect areas, the mean difference in the bone-to-implant contact was significant for AE versus TPS (P = 0.010); all other comparisons were not significant. There were 18 membrane exposures in the 72 implant sites. Data were analyzed again to assess the impact of membrane complications. Using a 1-way analysis of variance, the bone-to-implant contact was compared between the sites with and without membrane complications. No significant differences were seen in the defect areas or in the non-defect areas between the sites with and without membrane complications. In this study, the bone-to-implant contact in regenerated bone was greatest when an HA-coated implant was used.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.