Abstract

In the present work, the possibility of using photofragmentation laser-induced fluorescence (PFLIF) for thermometry in different reacting flows is investigated. Hydroxyl (OH) fragments are created by UV-laser (266 nm) fragmentation of hydrogen peroxides (H2O2 and HO2), whereupon the fluorescence, induced while scanning the wavelength of a second laser across the A2Σ+(v = 1)–X2Π(v = 0) absorption band (around 282 nm) of the generated OH fragments, is collected and detected. The temperature is determined by fitting simulated OH-excitation spectra of different temperatures to the experimentally recorded spectrum. In combustion, hydrogen peroxides are intermediate species formed during the low-temperature oxidation of the fuel, and hence they are present in a region covering a wide temperature span, ranging from unburnt to burnt gas temperatures. Thus, LIF of OH photofragments stemming from hydrogen peroxides allows for thermometry covering a wider temperature range than LIF of naturally present OH radicals. There is another important advantage of the concept in that the temperature sensitivity of OH excitation spectra is greater at lower temperatures. The method is demonstrated for two-dimensional (2-D) thermometry in three different measurement situations, namely a free flow of vaporized H2O2 at room temperature, a preheated mixture of CH4/N2/O2/O3 at intermediate temperatures (300–600 K), where the OH fragments stem from photodissociation of O3 followed by chemical reactions, and in an optical homogeneous charge compression ignition (HCCI) engine prior to ignition, i.e. at elevated pressures and temperatures. It is found that the technique performs well in all three cases, with measured temperatures in good agreement with thermocouple readings, for the two first cases, and with temperatures calculated based on the ideal gas law using measured pressure traces as input for the engine measurements. The quantitative 2-D temperature images acquired in the engine experiments reveal inhomogeneous temperature distributions, clearly illustrating the capacity of the technique to yield crucial experimental input to engine modelers and designers. The accuracy of the technique in the temperature range 300–600 K is lower than 23 K. For the room temperature case the precision is 4.3%, corresponding to 12 K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.