Abstract
The application of in-situ testing to the design and evaluation of a large sand densification project for the Jebba Hydroelectric Development is described. Correlation between the standard penetration test (SPT) N-value and the cone penetration test (CPT) tip resistance was established so that the CPT could be used for the major portion of the project after the feasibility study and liquefaction analysis were done using the SPT. Correlations between CPT tip resistance, relative density and depth were used successfully to assure that the required ground improvement had been achieved. Attempts to define the bedrock profile beneath thick alluvial sand deposits at this site by seismic refraction yielded poor results.