Abstract

BackgroundGrip strength is a variable which may be important to measure and follow in various populations. A new dynamometer with high accuracy and sensitivity has recently been developed to assess grip strength. The objectives of this work were to provide norms of maximal isometric grip strength measured with this new dynamometer (the MyoGrip device), to assess the reliability of measurements, to compare the measurements obtained with MyoGrip and Jamar dynamometers and finally to establish predictive equations from a population of healthy subjects (children and adults).MethodsMeasurements of maximal isometric grip strength using the MyoGrip and the Jamar (which is considered as the gold-standard) were performed on 346 healthy subjects aged from 5 to 80 years. Test-retest reliability for both devices was assessed on 77 subjects. Predictive equations were computed on subjects younger than 60 years of age in order to avoid the effects of aging on strength.ResultsThis study provides norms for isometric grip strength for health subjects from 5 to 80 years. Reliability of the MyoGrip device was excellent (intraclass correlation coefficient: 0.967). Despite good correlation between devices, the Jamar tended to overestimate maximal grip strength by about 14 %. A single predictive equation for men and women, adults and children incorporating hand circumference only can be used to compute the predicted theoretical maximal grip strength.ConclusionsThe MyoGrip device is a reliable tool for measuring isometric grip strength. Owing to its unique metrological features, it can be used in very weak patients or in any situation where high precision and accuracy are required.

Highlights

  • Grip strength is a variable which may be important to measure and follow in various populations

  • The development of a new dynamometer was motivated by the fact that none of the hand grip dynamometers on the market were adapted to very weak patients

  • Patients suffering from some disabling disorders such as Duchenne Muscular Dystrophy (DMD) or Spinal Muscular Atrophy (SMA) could not be reliably be evaluated as devices were not adapted to their weakness

Read more

Summary

Introduction

Grip strength is a variable which may be important to measure and follow in various populations. The objectives of this work were to provide norms of maximal isometric grip strength measured with this new dynamometer (the MyoGrip device), to assess the reliability of measurements, to compare the measurements obtained with MyoGrip and Jamar dynamometers and to establish predictive equations from a population of healthy subjects (children and adults). The Jamar dynamometer is the most widely reported device used to measure grip strength [3,4,5,6,7,8,9,10]. Eighty percent of occupational therapy schools and clinics in the United States use the Jamar dynamometer as their usual instrument to assess grip strength [2]. It has a peak-hold needle that automatically retains the highest reading until reset

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)